{CURRENT,VOLTAGE}_AVG are actually {CURRENT,VOLTAGE}_NOW (the EC code
directly passes through the value from the gas gauge instead of the
internally used average). We retain {CURRENT,VOLTAGE}_AVG as an alias
for compatibility reasons, it will be removed later.
Signed-off-by: Sascha Silbe <sascha-pgp@silbe.org>
[ pgf@laptop.org: added VOLTAGE_NOW, aliased to VOLTAGE_AVG ]
Signed-off-by: Paul Fox <pgf@laptop.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
CHARGE_NOW is needed by some user space software (read: UPower) for
internal calculations.
This patch violates the power supply class definition (as we already
do for CAPACITY though it isn't as obvious there), but this is the best
we can do without adding rather sophisticated algorithms to either the EC
or UPower.
Signed-off-by: Sascha Silbe <sascha-pgp@silbe.org>
Signed-off-by: Paul Fox <pgf@laptop.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Some user space software (read: UPower) uses CHARGE_FULL_DESIGN for internal
calculations. The design capacity of the OLPC batteries is effectively fixed
and only needs to be exported.
Signed-off-by: Sascha Silbe <sascha-pgp@silbe.org>
Signed-off-by: Paul Fox <pgf@laptop.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The XO-1.5 does not support the ambient temperature property.
Create a separate list of properties for that configuration where
ambient temperature is not included, and apply the correct property
list at runtime.
Signed-off-by: Daniel Drake <dsd@laptop.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
When the driver was updated to be endian neutral (8e9c7716c)
the signed part of the s16 values was lost. This is because be16_to_cpu()
returns an unsigned value. This patch casts the values back to a s16
number prior to the the implicit cast up to an int.
Signed-off-by: Richard A. Smith <richard@laptop.org>
Signed-off-by: Daniel Drake <dsd@laptop.org>
Cc: <stable@kernel.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
drivers/power/olpc_battery.c:387: error: unknown field 'owner' specified in initializer
drivers/power/olpc_battery.c:387: warning: excess elements in struct initializer
drivers/power/olpc_battery.c:387: warning: (near initialization for 'olpc_bat_eeprom.attr')
The .owner field has been dropped from the attr struct.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
This allows bin_attr->read,write,mmap callbacks to check file specific data
(such as inode owner) as part of any privilege validation.
Signed-off-by: Chris Wright <chrisw@sous-sol.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This adds a new sysfs file called 'charge_type' which displays the
type of charging (unknown, n/a, trickle charge, or fast charging).
This allows things like battery diagnostics to determine what the
battery/EC is doing without resorting to changing the 'status' sysfs
output.
Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Grab the error code from EC_BAT_ERRCODE and let the user see it (rather
than attempting to decode it as we do with PROP_HEALTH) with a separate
error sysfs file.
Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This reverts commit 8efe444038 and
4cbc76eadf.
Richard@laptop.org was apparently using CAPACITY_LEVEL for debugging
battery/EC problems, and was upset that it was removed. This readds it.
Conflicts:
Documentation/power_supply_class.txt
Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
There are times when the battery is present but trickle charging,
and the EC sets only the TRICKLE bit. So we must check for the bit
when we're checking the charging/present status.
Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The eeprom read function was placing values into the wrong place in
'buf'; we were starting from buf[off], rather than buf[0].
Also, the for loop that we were using was much uglier than it needed to
be. This cleans it up a bit.
Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Signed-off-by: Harvey Harrison <harvey.harrison@gmail.com>
Acked-by: Andres Salomon <dilinger@queued.net>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
As Richard Smith pointed out, ACR * 6250 / 15 provides for less
precision loss than ACR * 4167 / 10, _and_ it doesn't overflow. Switch
to using that equation for CHARGE_COUNTER.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: "Richard A. Smith" <richard@laptop.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This adds PROP_CHARGE_COUNTER to the power supply class (documenting it
as well). The OLPC battery driver uses this for spitting out its ACR
values (in uAh). We have some rounding errors (the data sheet claims
416.7, the math actually works out to 416.666667, so we're forced to
choose between overflows or precision loss. I chose precision loss,
and stuck w/ data sheet values), but I don't think anyone will care
that much.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Refuse to run with an EC < 0x44. We're playing it safe, and this is a pretty
old EC version.
Also, add a comment about why we're checking the EC version.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Move portions of the massive switch statement into functions. The layout of
this thing has already caused one bug (a break in the wrong place), it needed
to shrink.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This allows you to dump 0x60 bytes from the battery's EEPROM (starting at
address 0x20). Note that it does an EC command for each byte, so it's pretty
slow. OTOH, if you want to grab just a single byte from somewhere in the
EEPROM, you can do something like:
dd bs=1 count=1 skip=16 if=/sys/class/power_supply/olpc-battery/eeprom | od -x
Userspace battery collection/logging information needs this.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This adds serial number support to the OLPC battery driver.
Signed-off-by: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andres Salomon <dilinger@debian.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This adds support for OLPC XO hardware. Open Firmware on XOs don't contain
the VSA, so it is necessary to emulate the PCI BARs in the kernel. This also
adds functionality for running EC commands, and a CONFIG_OLPC.
A number of OLPC drivers depend upon CONFIG_OLPC.
olpc_ec_timeout is a hack to work around Embedded Controller bugs.
[akpm@linux-foundation.org: build fix]
[akpm@linux-foundation.org: geode_has_vsa build fix]
[akpm@linux-foundation.org: olpc_register_battery_callback doesn't exist]
Signed-off-by: Andres Salomon <dilinger@debian.org>
Acked-by: Ingo Molnar <mingo@elte.hu>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: Andi Kleen <ak@suse.de>
Cc: Jordan Crouse <jordan.crouse@amd.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The CAPACITY_LEVEL stuff defines various levels of charge; however, what
is the difference between them? What differentiates between HIGH and NORMAL,
LOW and CRITICAL, etc?
As it appears that these are fairly arbitrary, we end up making such policy
decisions in the kernel (or in hardware). This is the sort of decision that
should be made in userspace, not in the kernel.
If the hardware does not support _CAPACITY and it cannot be easily calculated,
then perhaps the driver should register a custom CAPACITY_LEVEL attribute;
however, userspace should not become accustomed to looking for such a thing,
and we should certainly not encourage drivers to provide CAPACITY_LEVEL
stubs.
The following removes support for POWER_SUPPLY_PROP_CAPACITY_LEVEL. The
OLPC battery driver is the only driver making use of this, so it's
removed from there as well.
Signed-off-by: Andres Salomon <dilinger@debian.org>
Signed-off-by: David Woodhouse <dwmw2@infradead.org>