1

reset: reset-meson: Add support for Amlogic T7 SoC reset controller

There are 7 sets of Reset Source in Amlogic T7 SoC reset controller,
and the offset between base and level registers is 0x40.
Add a new compatible string and struct meson_reset_param to support
the reset controller on T7 SoC.

Signed-off-by: Zelong Dong <zelong.dong@amlogic.com>
Signed-off-by: Kelvin Zhang <kelvin.zhang@amlogic.com>
Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org>
Link: https://lore.kernel.org/r/20240422-t7-reset-v2-2-cb82271d3296@amlogic.com
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
This commit is contained in:
Zelong Dong 2024-04-22 19:11:44 +08:00 committed by Philipp Zabel
parent 47c270a9bf
commit b062ef2907

View File

@ -102,6 +102,11 @@ static const struct meson_reset_param meson_s4_param = {
.level_offset = 0x40,
};
static const struct meson_reset_param t7_param = {
.reg_count = 7,
.level_offset = 0x40,
};
static const struct of_device_id meson_reset_dt_ids[] = {
{ .compatible = "amlogic,meson8b-reset", .data = &meson8b_param},
{ .compatible = "amlogic,meson-gxbb-reset", .data = &meson8b_param},
@ -109,6 +114,7 @@ static const struct of_device_id meson_reset_dt_ids[] = {
{ .compatible = "amlogic,meson-a1-reset", .data = &meson_a1_param},
{ .compatible = "amlogic,meson-s4-reset", .data = &meson_s4_param},
{ .compatible = "amlogic,c3-reset", .data = &meson_s4_param},
{ .compatible = "amlogic,t7-reset", .data = &t7_param},
{ /* sentinel */ },
};
MODULE_DEVICE_TABLE(of, meson_reset_dt_ids);