1

thermal/drivers/qcom/tsens-v0_1: Fix mdm9607 slope values

According to the msm-3.18 vendor kernel from Qualcomm [1], mdm9607 uses
a non-standard slope value of 3000 (instead of 3200) for all sensors.
Fill it properly similar to the 8939 code added recently.

[1]: https://git.codelinaro.org/clo/la/kernel/msm-3.18/-/blob/LE.UM.4.3.2.r1-04200-9x07/arch/arm/boot/dts/qcom/mdm9607.dtsi#L875

Fixes: a2149ab815 ("thermal/drivers/qcom/tsens-v0_1: Add support for MDM9607")
Reviewed-by: Konrad Dybcio <konrad.dybcio@linaro.org>
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Signed-off-by: Stephan Gerhold <stephan.gerhold@kernkonzept.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20230508-msm8909-tsens-v5-2-5eb632235ba7@kernkonzept.com
This commit is contained in:
Stephan Gerhold 2023-06-07 12:47:45 +02:00 committed by Daniel Lezcano
parent c631da1f19
commit 6812d1dfbc

View File

@ -234,6 +234,16 @@ static int __init init_8939(struct tsens_priv *priv) {
return init_common(priv);
}
static int __init init_9607(struct tsens_priv *priv)
{
int i;
for (i = 0; i < priv->num_sensors; ++i)
priv->sensor[i].slope = 3000;
return init_common(priv);
}
/* v0.1: 8226, 8916, 8939, 8974, 9607 */
static struct tsens_features tsens_v0_1_feat = {
@ -345,9 +355,15 @@ struct tsens_plat_data data_8974 = {
.fields = tsens_v0_1_regfields,
};
static const struct tsens_ops ops_9607 = {
.init = init_9607,
.calibrate = tsens_calibrate_common,
.get_temp = get_temp_common,
};
struct tsens_plat_data data_9607 = {
.num_sensors = 5,
.ops = &ops_v0_1,
.ops = &ops_9607,
.feat = &tsens_v0_1_feat,
.fields = tsens_v0_1_regfields,
};