clk: ralink: mtmips: quiet unused variable warning

When CONFIG_OF is disabled then the matching table is not referenced and
the following warning appears:

drivers/clk/ralink/clk-mtmips.c:821:34: warning: unused variable 'mtmips_of_match' [-Wunused-const-variable]
821 |   static const struct of_device_id mtmips_of_match[] = {
    |                          ^

There are two match tables in the driver: one for the clock driver and the
other for the reset driver. The only difference between them is that the
clock driver uses 'data' and does not have 'ralink,rt2880-reset' compatible.
Both just can be merged into a single one just by adding the compatible
'ralink,rt2880-reset' entry to 'mtmips_of_match[]', which will allow it to
be used for 'mtmips_clk_driver' (which doesn't use the data) as well as for
'mtmips_clk_init()' (which doesn't need get called for 'ralink,rt2880-reset').

Doing in this way ensures that 'CONFIG_OF' is not disabled anymore so the
above warning disapears.

Fixes: 6f3b15586e ("clk: ralink: add clock and reset driver for MTMIPS SoCs")
Reported-by: kernel test robot <lkp@intel.com>
Closes: https://lore.kernel.org/oe-kbuild-all/202307242310.CdOnd2py-lkp@intel.com/
Suggested-by: Arnd Bergmann <arnd@kernel.org>
Signed-off-by: Sergio Paracuellos <sergio.paracuellos@gmail.com>
Link: https://lore.kernel.org/r/20230827023932.501102-1-sergio.paracuellos@gmail.com
Reviewed-by: Nathan Chancellor <nathan@kernel.org>
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
This commit is contained in:
Sergio Paracuellos 2023-08-27 04:39:32 +02:00 committed by Stephen Boyd
parent 14aaccbd34
commit 6191023134

View File

@ -821,6 +821,10 @@ static const struct mtmips_clk_data mt76x8_clk_data = {
};
static const struct of_device_id mtmips_of_match[] = {
{
.compatible = "ralink,rt2880-reset",
.data = NULL,
},
{
.compatible = "ralink,rt2880-sysc",
.data = &rt2880_clk_data,
@ -1088,25 +1092,11 @@ static int mtmips_clk_probe(struct platform_device *pdev)
return 0;
}
static const struct of_device_id mtmips_clk_of_match[] = {
{ .compatible = "ralink,rt2880-reset" },
{ .compatible = "ralink,rt2880-sysc" },
{ .compatible = "ralink,rt3050-sysc" },
{ .compatible = "ralink,rt3052-sysc" },
{ .compatible = "ralink,rt3352-sysc" },
{ .compatible = "ralink,rt3883-sysc" },
{ .compatible = "ralink,rt5350-sysc" },
{ .compatible = "ralink,mt7620-sysc" },
{ .compatible = "ralink,mt7628-sysc" },
{ .compatible = "ralink,mt7688-sysc" },
{}
};
static struct platform_driver mtmips_clk_driver = {
.probe = mtmips_clk_probe,
.driver = {
.name = "mtmips-clk",
.of_match_table = mtmips_clk_of_match,
.of_match_table = mtmips_of_match,
},
};