iio: chemical: bme680: Remove duplicate register read
The LSB of the gas register was read first to check if the following check was correct and then the MSB+LSB were read together. Simplify this by reading together the MSB+LSB immediately. Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Link: https://patch.msgid.link/20240609233826.330516-7-vassilisamir@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
4d879ba0a6
commit
5a38766897
@ -46,7 +46,7 @@
|
||||
#define BME680_RSERROR_MASK GENMASK(7, 4)
|
||||
#define BME680_REG_RES_HEAT_0 0x5A
|
||||
#define BME680_REG_GAS_WAIT_0 0x64
|
||||
#define BME680_ADC_GAS_RES_SHIFT 6
|
||||
#define BME680_ADC_GAS_RES GENMASK(15, 6)
|
||||
#define BME680_AMB_TEMP 25
|
||||
|
||||
#define BME680_REG_CTRL_GAS_1 0x71
|
||||
|
@ -767,7 +767,7 @@ static int bme680_read_gas(struct bme680_data *data,
|
||||
int ret;
|
||||
__be16 tmp = 0;
|
||||
unsigned int check;
|
||||
u16 adc_gas_res;
|
||||
u16 adc_gas_res, gas_regs_val;
|
||||
u8 gas_range;
|
||||
|
||||
/* Set heater settings */
|
||||
@ -792,11 +792,14 @@ static int bme680_read_gas(struct bme680_data *data,
|
||||
return -EBUSY;
|
||||
}
|
||||
|
||||
ret = regmap_read(data->regmap, BME680_REG_GAS_R_LSB, &check);
|
||||
ret = regmap_bulk_read(data->regmap, BME680_REG_GAS_MSB,
|
||||
&tmp, sizeof(tmp));
|
||||
if (ret < 0) {
|
||||
dev_err(dev, "failed to read gas_r_lsb register\n");
|
||||
dev_err(dev, "failed to read gas resistance\n");
|
||||
return ret;
|
||||
}
|
||||
gas_regs_val = be16_to_cpu(tmp);
|
||||
adc_gas_res = FIELD_GET(BME680_ADC_GAS_RES, gas_regs_val);
|
||||
|
||||
/*
|
||||
* occurs if either the gas heating duration was insuffient
|
||||
@ -804,20 +807,12 @@ static int bme680_read_gas(struct bme680_data *data,
|
||||
* heater temperature was too high for the heater sink to
|
||||
* reach.
|
||||
*/
|
||||
if ((check & BME680_GAS_STAB_BIT) == 0) {
|
||||
if ((gas_regs_val & BME680_GAS_STAB_BIT) == 0) {
|
||||
dev_err(dev, "heater failed to reach the target temperature\n");
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
ret = regmap_bulk_read(data->regmap, BME680_REG_GAS_MSB,
|
||||
&tmp, sizeof(tmp));
|
||||
if (ret < 0) {
|
||||
dev_err(dev, "failed to read gas resistance\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
gas_range = check & BME680_GAS_RANGE_MASK;
|
||||
adc_gas_res = be16_to_cpu(tmp) >> BME680_ADC_GAS_RES_SHIFT;
|
||||
gas_range = FIELD_GET(BME680_GAS_RANGE_MASK, gas_regs_val);
|
||||
|
||||
*val = bme680_compensate_gas(data, adc_gas_res, gas_range);
|
||||
return IIO_VAL_INT;
|
||||
|
Loading…
Reference in New Issue
Block a user